Output Power Capacity 670 Watts / 1000 VA
Max Configurable Power 670 Watts / 1000 VA
Nominal Output Voltage 230V
Output Voltage Note Configurable for 220 : 230 or 240
Output Voltage Distortion Less than 5% at full load
Output Frequency (sync to mains)
47 - 53 Hz for 50 Hz nominal,57 - 63 Hz for 60 Hz nominal
Crest Factor up to 5 : 1
Waveform Type Sine wave
Output Connections (4) IEC 320 C13, (2) IEC Jumpers
Input Nominal Input Voltage 230V
Input Frequency 50/60 Hz +/- 3 Hz (auto sensing)
Input Connections IEC-320 C14
Input voltage range for main operations 160 - 280V
Input voltage adjustable range for mains operation 151 - 302V
Run Time:
Typical Backup Time at Half Load 31.6 minutes (335 Watts)
Typical Backup Time at Full Load 9.1 minutes (670 Watts)
Output Power Capacity 640 Watts / 1000 VA
Max Configurable Power 640 Watts / 1000 VA
Nominal Output Voltage 230V
Output Voltage Note Configurable for 220 : 230 or 240
Output Voltage Distortion Less than 5% at full load
Output Frequency (sync to mains)
47 - 53 Hz for 50 Hz nominal,57 - 63 Hz for 60 Hz nominal
Crest Factor up to 5 : 1
Waveform Type Sine wave
Output Connections (4) IEC 320 C13, (2) IEC Jumpers
Input Nominal Input Voltage 230V
Input Frequency 50/60 Hz +/- 3 Hz (auto sensing)
Input Connections IEC-320 C14
Input voltage range for main operations 160 - 286V
Input voltage adjustable range for mains operation 151 - 302V
Run Time:
Typical Backup Time at Half Load 14.5 minutes (320 Watts)
Typical Backup Time at Full Load 5.4 minutes (640 Watts)
Input voltage range for main operations 160 - 285V
Input voltage adjustable range for mains operation 151 - 302V
Input Breaker Capacity 20.0 A
Includes: CD with software, Documentation CD, Installation guide,
Rack Mounting support rails, Removable support feet,
Smart UPS signalling RS-232 cable, USB cable
Output Power Capacity 1980 Watts / 2200 VA
Max Configurable Power 1980 Watts / 2200 VA
Nominal Output Voltage 230V
Output Voltage Note Configurable for 220 : 230 or 240 nominal output voltage
Output Voltage Distortion Less than 5% at full load
Output Frequency (sync to mains)
47 - 53 Hz for 50 Hz nominal,57 - 63 Hz for 60 Hz nominal
Crest Factor up to 5 : 1
Waveform Type Sine wave
Output Connections (8) IEC 320 C13, (1) IEC 320 C19
(2) IEC Jumpers
Input Nominal Input Voltage
230V Input Frequency
50/60 Hz +/- 3 Hz (auto sensing)
Input Connections IEC-320 C20
Schuko CEE 7 / EU1-16P British BS1363A
Input voltage range for main operations 160 - 286V
Input voltage adjustable range for mains operation 151 - 302V
Run Time:
Typical Backup Timeat Half Load 15.7 minutes (990 Watts)
Typical Backup Time at Full Load 5.2 minutes (1980 Watts)
Output Power Capacity 2700 Watts / 3000 VA
Max Configurable Power 2700 Watts / 3000 VA
Nominal Output Voltage 230V
Output Voltage Note
Configurable for 220 : 230 or 240 nominal output voltage
Output Voltage Distortion Less than 5% at full load
Output Frequency (sync to mains)
47 - 53 Hz for 50 Hz nominal,57 - 63 Hz for 60 Hz nominal
Crest Factor up to 5 : 1
Waveform Type Sine wave
Output Connections (8) IEC 320 C13, (1) IEC 320 C19
(2) IEC Jumpers
Input Nominal Input Voltage 230V
Input Frequency 50/60 Hz +/- 3 Hz (auto sensing)
Input Connections IEC-320 C20
Schuko CEE 7 / EU1-16P
British BS1363A
Input voltage range for main operations 160 - 286V
Input voltage adjustable range for mains operation 151 - 302V
Run Time:
Typical Backup Time at Half Load 11.3 minutes (1350 Watts)
Typical Backup Time at Full Load 3.0 minutes (2700 Watts)
Output Power Capacity 4000 Watts / 5000 VA
Max Configurable Power 4000 Watts / 5000 VA
Nominal Output Voltage 230V
Output Voltage Note
Configurable for 220 : 230 or 240 nominal output voltage
Efficiency at Full Load 96%
Output Voltage Distortion Less than 5% at full load
Output Frequency (sync to mains) 47 - 53 Hz for 50 Hz nominal
Crest Factor 3 : 1
Waveform Type Sine wave
Output Connections (8) IEC 320 C13, (2) IEC 320 C19
(4) IEC Jumpers Input
Nominal Input Voltage 230V
Input Frequency 50/60 Hz +/- 3 Hz (auto sensing)
Input Connections Hard Wire 3-wire
Input voltage range for main operations 160 - 286V
Input voltage adjustable range for mains operation 151 - 302V
Typical Backup Time at Half Load 26.7 minutes (2000 Watts)
Typical Backup Time at Full Load 9.4 minutes (4000 Watts)