Output Power Capacity 480 Watts / 750 VA
Max Configurable Power 480 Watts / 750 VA
Nominal Output Voltage 230V
Output Voltage Distortion Less than 5% at full load
Output Frequency (sync to mains)
47 - 53 Hz for 50 Hz nominal,57 - 63 Hz for 60 Hz nominal
Crest Factor up to 5 : 1
Waveform Type Sine wave
Output Connections (4) IEC 320 C13, (2) IEC Jumpers
InputNominal Input Voltage 230V
Input Frequency 50/60 Hz +/- 3 Hz (auto sensing)
Input Connections IEC-320 C14
Input voltage range for main operations 160 - 286V
Input voltage adjustable range for mains operation 151 - 302V
Run Time:
Typical Backup Time at Half Load 23.6 minutes (240 Watts)
Typical Backup Time at Full Load 7.1 minutes (480 Watts)
Includes:
CD with soft., Rack Mounting brackets, Rack Mounting support rails Smart UPS signalling
RS-232 cable, USB cable, User Manual
Output Power Capacity 670 Watts / 1000 VA
Max Configurable Power 670 Watts / 1000 VA
Nominal Output Voltage 230V
Output Voltage Note Configurable for 220 : 230 or 240
Output Voltage Distortion Less than 5% at full load
Output Frequency (sync to mains)
47 - 53 Hz for 50 Hz nominal,57 - 63 Hz for 60 Hz nominal
Crest Factor up to 5 : 1
Waveform Type Sine wave
Output Connections (4) IEC 320 C13, (2) IEC Jumpers
Input Nominal Input Voltage 230V
Input Frequency 50/60 Hz +/- 3 Hz (auto sensing)
Input Connections IEC-320 C14
Input voltage range for main operations 160 - 280V
Input voltage adjustable range for mains operation 151 - 302V
Run Time:
Typical Backup Time at Half Load 31.6 minutes (335 Watts)
Typical Backup Time at Full Load 9.1 minutes (670 Watts)
Output Power Capacity 640 Watts / 1000 VA
Max Configurable Power 640 Watts / 1000 VA
Nominal Output Voltage 230V
Output Voltage Note Configurable for 220 : 230 or 240
Output Voltage Distortion Less than 5% at full load
Output Frequency (sync to mains)
47 - 53 Hz for 50 Hz nominal,57 - 63 Hz for 60 Hz nominal
Crest Factor up to 5 : 1
Waveform Type Sine wave
Output Connections (4) IEC 320 C13, (2) IEC Jumpers
Input Nominal Input Voltage 230V
Input Frequency 50/60 Hz +/- 3 Hz (auto sensing)
Input Connections IEC-320 C14
Input voltage range for main operations 160 - 286V
Input voltage adjustable range for mains operation 151 - 302V
Run Time:
Typical Backup Time at Half Load 14.5 minutes (320 Watts)
Typical Backup Time at Full Load 5.4 minutes (640 Watts)
Rating: 3000 VA / 2400 W Format: Tower Technology : On-Line Input Voltage : Wide input voltage tolerance (from 140-276Vac) without battery usage Fully configurable using UPS Tools configuration software
Output voltage and frequency : 230 V, 50/60 Hz, Output Sockets: 8x IEC 320 C13 + 1 IEC 320 C19 Comunications: USB, RS232, Slot for Interface Communication
Battery Runtime 1/2 load 31min
Battery Runtime Full load 11min
Online double-conversion topology assures maximum reliability
Wide input voltage range appropriate for the harshest electrical environments
Tested for generator compatibility
Automatic bypass for fault tolerance
Optional SNMP communications provide remote network-based monitoring
Input voltage range for main operations 160 - 285V
Input voltage adjustable range for mains operation 151 - 302V
Input Breaker Capacity 20.0 A
Includes: CD with software, Documentation CD, Installation guide,
Rack Mounting support rails, Removable support feet,
Smart UPS signalling RS-232 cable, USB cable
Battery Runtime 1/2 load 16min
Battery Runtime Full load 6min
Online double-conversion topology assures maximum reliability
Wide input voltage range appropriate for the harshest electrical environments
Tested for generator compatibility
Automatic bypass for fault tolerance
Optional SNMP communications provide remote network-based monitoring